Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.
New Feature: Part Finder

Ductless 30,000 Btuh Heat Pump Single Zone w/ Basepan Heater 208/230-1 (Matches 40M models)

Item: 38MAQB30R--3
MFR: 38MAQB30R--3

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
Equipment part list is available.
What’s the price?
Sign in for pricing.
Decrease quantity
Increase quantity

Description

The 38MA*R series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.The ductless system permits creative solutions to design problems such as:

  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork

Historical renovations or any application where preserving the look of the original structure is essential.The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. The compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer.The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
When sound ordinances and proximity to neighbors demand quiet operation, the 38MA*R unit is the right choice. The advanced, horizontal airflow design distributes air more evenly over the coil.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 38MA*R units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless split system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units (High Walls).These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 38MA*R ductless split systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless split system indoor and outdoor units are designed to provide years of trouble-free operation.
The indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-currentprotection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep (in some indoor models) feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply-airfans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY-TO-USE CONTROLS
The indoor units have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless split systems to your application is easily accomplished. Adding a condensate pump accessory to the indoor fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Documentation

Specifications

Weight139.8 Pound (lb.)
Width37.24 Inches (in)
Height31.89 Inches (in)
Country of OriginCHN
UPC or Barcode1P38MAQB30R--3
Hazardous MaterialNo
EPA Cert RequiredNo
Length16.14 Inches (in)
Battery BackupNo
BrandCarrier,Bryant
CertificationsAHRI Certified
CFM2130
ColorWhite
Cooling Capacity30000
Cycle/Hertz60
EER12
Equipment TypeHeat Pump
ETL CertifiedNo
ETL ListedYes
Heating Capacity30000
HSPF9.4
InverterYes
ISO CodeCN
Liquid Line Fitting3/8"
Liquid Line Size3/8"
Maximum Fuse Size30
Maximum Piping Length164'
Minimum Circuit Amps20
Number of HVAC Zones1
PhaseSingle
Product Family38MAR
Rated Load Amps15
RefrigerantR-410a
SEER20
Sound Level (dBA)60.5
StageVariable
Suction Line Fitting5/8"
Suction Line Size5/8"
TierMid
Tonnage2.5
UL ListedNo
UL RecognizedNo
Voltage208-230 VAC
Zone CapabilitySingle